<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-19 03-05-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 5/5, 30 dBuV R-CB
Pilot RDS Phase Difference
6.5 kHz 2.6 kHz 83 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
16 kHz 40 kHz 17413 0,0230
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,4 dBr -0,98 dBr -0,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-CB " 250D 9 (Varied) 1 0 0 0 3:05, 19.07.2024
RT
"Zpravy z "
AF EON
88.2, 103.9, 106.4 MHz -
FM Scope Max at: 40 kHz MIN: 16 kHz % above 77 kHz: 0,0230 Acquired: 2024/07/19 3:05:37 Total samples: 17413 Equivalent time: 0:14:30 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -0,5 dBr MIN: -1,4 dBr AVE: -0,98 dBr % above 0,2 dBr: 0,0 Last value: -0,7 dBr (2024/07/19 3:05:37) 02:52 02:54 02:56 02:58 03:00 03:02 03:04 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality